ATS
- Reliable solution for residential and condominium applications on gates up to 5 m and columns with a C-MAX up to 200 mm. ATS is provided with a bevel gear for smoother movement. Robust and durable with a die-cast aluminium structure for longer life span.
Max. leaf length |
Max. leaf weight |
Use |
C max. |
|---|---|---|---|
up to 5 m |
up to 800 kg |
Continuous duty |
200 mm |
Our range
Main features
- Designed for applications with C Max. up to 200 mm.
- Sturdy and durable with die-cast aluminium supporting structure.
- Reducer with bevel gear for greater fluidity of movement.
- Release system, with the possibility of remote control.
- Developed with CONNECT technology for remote digital control via gateway or locally via CAME KEY.
- Complies with regulation (EU) 2023/826, for energy consumption in off, stand-by and networked stand-by modes.
CAME CONNECT Ready
This automation is CAME CONNECT ready, easily linking to the Cloud through gateways like Ethernet, Wi-Fi, or GSM. CAME CONNECT provides significant benefits to both installers and end users. Installers can use the CAME Setup App to configure and monitor systems locally or remotely, enabling real-time maintenance and troubleshooting without on-site visits, which allows for rapid intervention when needed. End users enjoy control and convenience via the CAME Automation App, accessing their automation from anywhere.
Great flexibility with “C” max. up to 200 mm

ATS offers a universal solution, ideal for residential contexts of all sizes. Its high versatility, combined with the telescopic extension, allows it to adapt perfectly to pillars of different depths, managing installations with a C-Max of up to 200 mm.
Safety and Performance

The ATS series is rigorously tested to meet European standard EN 12453, ensuring compliance with safety and performance requirements for automatic closing systems that may interact with people. This standard guarantees robust user protection by regulating impact forces.
Operational limits
| Models | Max. length of leaf (m) | Max. weight of leaf (kg) | Max. door length / weight | Max. door length / weight | Max. door length / weight | Max. door length / weight | Max. door length / weight | Max. door length / weight | Max. door length / weight | Max. door length / weight | Max. door length / weight | Max. leaf opening (°) | Max. surface of the door (m²) | Max. traction force (N) | H max. door (m) – direct grip | H max. door (m) – chain transmission | H max. leaf (m) – sliding doors | Length / Max. weight (single door) | Length / Max. weight (single door) | Length / Max. weight (swing door) | Length / Max. weight (swing door) | Max. net clearance width (m) | Max. range of radio (m) | Max range of infrared beam (m) | Max clearance width of parking space (m) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 801MP-0050 | 3 | 800 | 3 m / 400 kg | 2,5 m / 600 kg | 2 m / 800 kg | m / kg | m / kg | m / kg | m / kg | m / kg | m / kg | 120 | m / kg | m / kg | m / kg | m / kg | |||||||||
| 801MP-0060 | 5 | 1000 | 5 m / 400 kg | 4 m / 500 kg | 3 m / 600 kg | 2,5 m / 800 kg | 2 m / 1000 kg | m / kg | m / kg | m / kg | m / kg | 120 | m / kg | m / kg | m / kg | m / kg | |||||||||
| 801MP-0090 | 3 | 800 | 3 m / 400 kg | 2,5 m / 600 kg | 2 m / 800 kg | m / kg | m / kg | m / kg | m / kg | m / kg | m / kg | 120 | m / kg | m / kg | m / kg | m / kg | |||||||||
| 801MP-0100 | 5 | 1000 | 5 m / 400 kg | 4 m / 500 kg | 3 m / 600 kg | 2,5 m / 800 kg | 2 m / 1000 kg | m / kg | m / kg | m / kg | m / kg | 120 | m / kg | m / kg | m / kg | m / kg | |||||||||
| 801MP-0070 | 3 | 800 | 3 m / 400 kg | 2,5 m / 600 kg | 2 m / 800 kg | m / kg | m / kg | m / kg | m / kg | m / kg | m / kg | 120 | m / kg | m / kg | m / kg | m / kg | |||||||||
| 801MP-0080 | 5 | 1000 | 5 m / 400 kg | 4 m / 500 kg | 3 m / 600 kg | 2,5 m / 800 kg | 2 m / 1000 kg | m / kg | m / kg | m / kg | m / kg | 120 | m / kg | m / kg | m / kg | m / kg | |||||||||
| 801MP-0110 | 3 | 800 | 3 m / 400 kg | 2,5 m / 600 kg | 2 m / 800 kg | m / kg | m / kg | m / kg | m / kg | m / kg | m / kg | 120 | m / kg | m / kg | m / kg | m / kg |
Technical data
| Models | Power supply (V) | Power supply to motor (V) | Power (W) | Standby consumption (W) | Current consumption (A) | Max. current consumption (A) | Max. power supply (V) | Current consumption at 24 V (mA) | Crown turns (rpm) | Duty/cycle (%) | Force (N) | Max. maneuvering speed (m/min) | Maneuvering time at 90° (s) | Cycles/hour | Cycles/Hour with 4 m leaf | Cycles/Hour with 10 m leaf | Manouvering speed (m/min) | Pinion module | Reduction ratio (i) | IP Protection rating | Operating temperature (°C) | Storage temperature (°C) | Motor’s heat protection (°C) | Length (mm) | Package dimensions (mm) | Weight (kg) | Torque (Nm) | Rpm speed (turns/min) | Weight lifted (kg)* | Duration of operation (min) | Combinations | Radio signal frequency (Mhz) | Batteries | Material | Bluetooth radio frequency (GHz) | Maximum speed measured at the end of the leaf (m/min) | Product standards | Compliance with directives | Max. current consumption (mA) | Wireless Standard | Container material | Relative humidity in operation (%) | Temperature reading precision (°C) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 801MP-0050 | 230 AC | 250 | 1 | 400 ÷ 3000 | 15 | 20 | 54 | -20 ÷ +55 ÷ | ÷ | 150 | 920 | 8.5 | x | ||||||||||||||||||||||||||||||
| 801MP-0060 | 230 AC | 250 | 1 | 400 ÷ 3000 | 20 | 20 | 54 | -20 ÷ +55 ÷ | ÷ | 150 | 1050 | 9 | x | ||||||||||||||||||||||||||||||
| 801MP-0090 | 230 AC | 250 | 1 | 400 ÷ 3000 | 15 | 20 | 54 | -20 ÷ +55 ÷ | ÷ | 150 | 920 | 8.5 | x | ||||||||||||||||||||||||||||||
| 801MP-0100 | 230 AC | 250 | 1 | 400 ÷ 3000 | 20 | 20 | 54 | -20 ÷ +55 ÷ | ÷ | 150 | 1050 | 9 | x | ||||||||||||||||||||||||||||||
| 801MP-0070 | 24 DC | 80 | 8 MAX | 400 ÷ 3000 | 15 ÷ 30 | CONTINUOUS DUTY | 54 | -20 ÷ +55 ÷ | ÷ | 920 | 7.5 | x | |||||||||||||||||||||||||||||||
| 801MP-0080 | 24 DC | 80 | 8 MAX | 400 ÷ 3000 | 15 ÷ 30 | CONTINUOUS DUTY | 54 | -20 ÷ +55 ÷ | ÷ | 1050 | 8 | x | |||||||||||||||||||||||||||||||
| 801MP-0110 | 24 DC | 80 | 8 MAX | 400 ÷ 3000 | 15 ÷ 30 | CONTINUOUS DUTY | 54 | -20 ÷ +55 ÷ | ÷ | 920 | 7.5 | x |